PD-12 Detector type gas detector
A suction type ATEX detector with a very strong design. Suitable to detect a wide range of flammable and toxic gases in industrial applications and locations with limited access. A unique detector in an ATEX enclosure with built in pump. There are 3 models available:
PD-12A for measurement of combustible gases in ppm range PD-12B for measurement of combustible gases in %LEL range PD-12C for measurement of combustible gases in %vol. range
Also available as SIL 1 version. |
- Small and lightweight with concentration and alarm display
- Extractive type with hydrogen explosion proof (Ex d IIB + H2 T4X)
- Detecting decreased flow rate function except PD-12C (option)
- Environmental friendly product
- Water and dust-proof construction (Degree of protection: IP65)
Detectable gases | |
---|---|
1,1,1,3,3-Pentafluorobutane | C4H5F5 |
Acetone | C3H6O |
Acetylene | C2H2 |
Butane | C4H10 |
Carbon dioxide | CO2 |
Carbon monoxide | CO |
Cyclohexane | C6H12 |
Ethanol | CH3CH2OH |
Ethylene | C2H4 |
Gasoline | Benzin |
Helium | He |
Hydrogen | H2 |
Isobutane | C4H10 |
Isopropyl alcohol | C3H8O |
LPG | LPG |
Methane | CH4 |
Methane | CH4 |
Methanol | CH4O |
n-Btane | C4H8 |
Oxygen | O2 |
Propane | C3H8 |
Propylene | C3H6 |
Model | PD-12A | PD-12B | PD-12C |
---|---|---|---|
Detection Principle | Hot wire semiconductor | Catalytic combustion | Thermal conductivity |
Measuring unit | ppm | %LEL | %vol. |
Gas Detected | As per specifications | ||
Sampling Method | As per specifications | ||
Suction Flow | Over 0.5L/min | ||
Detection Range | As per specifications | ||
Alarm Set Value | As per specifications | ||
Alarm Accuracy | Combustible gas: ±25% of alarm set value under identical conditions | ||
Toxic gas: ±30% of alarm set value under identical conditions | |||
Alarm Delay | Combustible gas: Within 30 seconds with 1.6 times of alarm set conditions | ||
Toxic gas: Within 60 seconds with 1.6 times of alarm set concentration | |||
Alarms | Gas alarm: Red LED lamp flashes | ||
Trouble alarm: Yellow LED lamp flashes (sensor disconnection, sensor zero drop,power supply voltage error, etc.) | |||
Display | Four-digit digital LED display | ||
Output | Gas concentration analog signal | ||
・4-20mADC (common to the negative side of power supply) | |||
Gas alarm contact or failure contact*1 (one stage only) | |||
・1a no-voltage contact output, Non-latching | |||
・Rated load: 0.5A at 250VAC or 0.5A at 30VDC (resistance load) | |||
Operation | At 4 points of magnetic switches | ||
Explosion-proof | II 2G Ex d IIB + H2 T4 Gb (ATEX)*2 | ||
Ex d IIB + H2 T4 X (TIIS) | |||
Degree of Protection | IP65 | ||
Applicable Cable | Cable outer diameter: 10.5mm to 14.5mm | ||
6-conductor shielded cable: CVV-S 1.25mm2 or 2.0mm2 | |||
Operating | -10 to +50 °C | ||
Temperature/Humidity*3 | 10 to 90 %RH (0 to 50 °C) | ||
Power Supply | 24 VDC (±20%) | ||
Power Consumption | 7.5W max. | ||
Dimensions | W133 x H260 x D132 mm (excluding protrusions) | ||
Weight | Approx. 5.2kg |
*1 Gas alarm contact is a standard issue. Please specify if you wish a failure contact.
*2 Some are not ATEX approved. For further information, please ask.
*3 No radical temperature or humidity changes and no condensing.